The termSchuko plug*Means nothing else than protective contact plug. Itu “Schuko plug systemis used worldwide and is a system of sockets and plugs. The Schuko plug has two contact pins with a diameter of 4.8 mm, a length of 19 mm, and a distance of 19 mm from each other. The outer conductor (phase) and the neutral conductor (N) are connected to these two contact pins.

Schuko plug with kink protection sleeve drawing

The third contact of the Steker Schuko is the protective contact. The green-yellow protective conductor is connected here. He is responsible for the safety and should divert fault currents. Sebagai contoh, a short circuit occurs in a closed circuit, and the current is diverted via the protective conductor. When the Schuko plug is plugged into the socket, the safe protective contact is established by the springs on the socket and the smooth contacts on the Schuko plug. This protective contact is the first on-site when plugging in, before the other two poles (L and N).

The connection of a Schuko plug

The connection of a Schuko plug
  1. Remove the Schuko plug cover.
  2. Unscrew the contact screws (until the opening for the connection wires is large enough).
  3. Strip the connection electrical cable (kira-kira. 4 – 5 cm). Carefully cut into the jacket with a sharp knife (be careful not to cut too deeply and damage the veins). Now move the coat back and forth and pull it off.
  4. To cut the wires correctly, hold the cable on the plug so that the jacket is just above the clamp of the strain relief.
  5. Bend the wires to the corresponding poles and cut the wires to the correct length. Namun, it should be added about a centimeter before the wires are then cut with a wire cutter be cut off. It is also important that the green-yellow protective conductor is a little longer than the other two. Sebagai contoh, if the strain relief fails due to constant use, the protective conductor is the least under tension and could still serve its purpose in the event of a fault.
  6. Now strip the wires with a wire stripper (kira-kira. 7 – 8 mm). Wire end ferrules on the wires and secure with a pair of crimping pliers. Important!!! Never pinch the flexible wires without ferrules.
  7. Insert the cable into the strain relief and let the jacket look about 2 mm over the fastening. Tighten the strain relief.
  8. Pertama, clamp the green-yellow wire into the terminal for the protective contact (middle terminal).
  9. Clamp the other two wires, the neutral conductor (N color blue) and the outer conductor (L color black, cokelat, or gray), into the two-pin contacts on the left and right. It doesn’t matter which wire is pinched on the left or the right, as the connector is not reverse polarity protected, and there are two ways to plug it in. It is only important to have a protective conductor on the protective contact in the middle !!!
  10. Now, check all the wires for a tight fit and arrange the wires neatly in the connector so that the fastening screw on the cover can cause no damage.
  11. Fasten the strain relief. Important! The strain relief must be clamped onto the cable jacket, not the wires!
  12. Unscrew the cover. Check. Ready.

Sekarang Giliran Anda

So that’s I understand how to connect the Schuko plug to a rubber cable?

Sekarang saya ingin menyerahkannya kepada Anda: Melalui artikel saya, do you understand how to connector the Schuko plug to a rubber cable?

Do you have a different point of view on how to connector the Schuko plug to a rubber cable? Atau pertanyaan lain?

Beri tahu saya dengan meninggalkan komentar cepat di bawah sekarang.

Saluran Youtube DCpowercord

BAGIKAN POSTINGAN INI

Kabel Listrik Eropa

Nama Produk

16 Kabel Listrik Eropa

Nama Produk

Nama Produk

LOGO-330

Tlak ke Pakar

Diskusikan tuntutan untuk Proyek Anda